Posted in Logic

Download Agilent 16517A, 16518A Synchronous State Logic Analyzer PDF

Read or Download Agilent 16517A, 16518A Synchronous State Logic Analyzer (service) PDF

Best logic books

Set Theory and the Continuum Problem (Dover Books on Mathematics)

A lucid, dependent, and entire survey of set concept, this quantity is drawn from the authors' colossal educating event. the 1st of 3 elements specializes in axiomatic set idea. the second one half explores the consistency of the continuum speculation, and the ultimate part examines forcing and independence effects.

Zermelo’s Axiom of Choice: Its Origins, Development, and Influence

This ebook grew out of my curiosity in what's universal to 3 disciplines: arithmetic, philosophy, and background. The origins of Zermelo's Axiom of selection, in addition to the talk that it engendered, definitely lie in that intersection. because the time of Aristotle, arithmetic has been involved alternately with its assumptions and with the items, akin to quantity and house, approximately which these assumptions have been made.

Finitely Axiomatizable Theories

This is often the single monograph dedicated to the expressibility of finitely axiomatizable theories, a classical topic in mathematical good judgment. the quantity summarizes investigations within the box that experience led to a lot of the present development, treating systematically all optimistic effects pertaining to expressibility.

Extra resources for Agilent 16517A, 16518A Synchronous State Logic Analyzer (service)

Sample text

A In the Format menu, select State Acquisition Mode Full Channel. b Touch the threshold field under each module pod and select ECL. "). If any channels are active (showing an asterisk "*" in a channel position) then select that pod channel assignment field. ") then touch Done. d Touch the channel assignment field for master card pod 1. Use the knob to scroll the cursor to the channel 3 position. Touch the asterisk field (*) to activate the channel. Repeat for all pods in the module. e Touch the clock selection field.

3–6 To perform the self-tests The self tests verify the correct operation of the module. Self tests can be performed all at once or one at a time. While testing the performance of the module, run the self tests all at once. If error messages appear during the self tests, refer to chapter 8 for a description of the message. Loading the PV (performance verification) operating system will overwrite all of the Agilent Technologies 16500-series module configurations. If you would like to keep the configurations, then save the configurations to disk prior to loading the PV system.

B Select Run-Single. The display should show alternating F0 and 0F for each state. Touch Stop to halt the acquisition. If alternating F0 and 0F does not appear, check the logic analyzer connections and grounding. If alternating F0 and 0F still does not appear, select Run-Repetitive, then use the knob to change the sample offset in 50 ps increments between –100 ps and 900 ps until the correct pattern appears on the display. c Touch Listing, then touch Compare. Touch Copy Listing to Reference. d Touch Specify Stop Measurement.